TM 5-3895-373-20
REFERENCE INFORMATION
FLOW GATE CONTROL CIRCUIT
Refer to TM 5-3895-373-10 for engine starting and equipment operating procedures. Refer to paragraph
2.10 for connecting and disconnecting STE/ICE-R test set to DCA.
Open gauge panel access door per TM
5-3895-373-10 to gain access to circuit
breaker CB2.
Remove
operator
switch
panel
per
paragraph 7.6 to gain access to flow
gate switch terminals.
If both flow gates fail, fault will probably
be found using procedures in first two
steps of flowchart.
Refer
to
paragraph
1.18.7
for
an
electrical system description for the flow
gate control circuit.
Press the reset button on the breaker if
unsure of the breaker condition.
If voltage is missing to only one flow
gate
actuator,
continue
diagnostic
procedure for related circuit only.
To
avoid
reversing
polarity
to
the
voltmeter, connect negative test lead to
equipment ground and use positive lead
to probe for voltage.
2-175