TM 5-3895-373-20REFERENCE INFORMATIONIGNITION/EMERGENCY STOP CIRCUITRemove operator switch panel per paragraph7.6 to gain access to emergency stop switchterminals.With switch pulled out, +12 vdc should be atboth normally-closed contacts.Refer to the electrical system diagram at theend of the manual for equipment wiring details.Refer to paragraph 7.21 for harness and leadwire repair.Gain access to emergency stop switchterminals per paragraph 15.2 step a.2-143