Section XVIII. MAINTENANCE OF TRANSFER VALVES
2-32. Transfer Valve.
a.
Removal. (Refer to fig. 2-37.)
(1)
Disconnect chain (17) with support bracket (14) from valve body (26) by removing
four capscrews (16) and lockwashers (15).
(2)
Disconnect pipe nut (9) and remove one gasket (7).
(3)
Disconnect drop pipe nut (3) and remove complete three-way valve assembly (28)
with attaching piping and adapter assembly (21).
(4)
Unscrew coupling (37) and remove gasket (7).
(5)
Loosen handle (23) and move hinge clamp (24) to gain access to clamp ring (22).
(6)
Remove clamp ring (22) by removing capscrew (38), nut (40), washer (39), and two
cotter pins (25) from clamp ring (22); remove hinge clamp (24) and spread clamp ring (22) to remove.
Lift out hand spray adapter (20) with attached nipple (19) and union (18). Spread ring (42) and re-
move chain (41).
b.
Installation. (Refer to fig. 2-37.)
( I )
Mount hand spray adapter (20) with attached nipple ( 19) and union (18) on valve
body (26) and secure with clamp ring (22). Tighten clamp ring (22) with capscrew (38), nut (40) and
washer (39).
(2) Install hinge clamp (24) on valve body (26) and secure with two cotter pins (25).
(3)
Attach coupling (37) with new gasket (7) to valve body (29).
(4)
Mount valve body (26) with pipe assembly (5) and gasket (7) on drop pipe (4). Secure
with drop pipe nut (3).
(5)
Install gasket (7) and connect pipe (8) to valve body (26). Secure with pipe nut (9).
(6)
Connect chain (17) with support bracket (14) to valve body and secure with, four
capscrews (16) and lockwashers (15).
(7)
Install chain (41) to ring (42) and attach to handspray adapter (20).
2-84