NOTES - CONTINUED:
disassemble entire unit, clean, re-oil and assemble.
5.
CLUTCH AND REDUCTION GEAR HOUSING.
Each 50 hours check level and maintain level to bottom
of level plug with OE/HDO. Each 500 hours change oil.
After refill operate for 5 minutes, check for leaks, check
level and bring to "FULL" mark. Drain when oil is warm.
6. ENGINE OIL FILTER. Each 100 hours, remove filter
element, clean housing and install new filter element.
After installing new filter element, fill crankcase, operate
engine for 5 minutes, check housing for leaks, check
crankcase oil level and bring to "FULL" mark.
7. ENGINE. Oil is to be changed each 100 hours.
Drain when lubricant is warm.
8. ENGINE OIL LEVEL HOT OR COLD CHECK. Cold
engine, oil level should be at high mark on dipstick. Hot
engine, oil level must be between high and low marks on
dipstick (allow to set 5 minutes before checking).
9. CRANKCASE BREATHER. Each 100 hours remove
breather, clean in approved dry cleaning solvent, dry and
Copy of this Lubrication Order will remain with the
re-oil with OE/HDO.
equipment at all times, instructions contained herein are
mandatory.
10. LUBRICANTS. The following is a list of lubricants
with military symbols and applicable specification
By order of the Secretary of the Army:
numbers.
JOHN A. WICKHAM, JR.
General, United States Army
OE/HDO
MIL-L-2104
Chief of Staff
GAA
MIL-G-10924
OEA
MIL-L-46167
OFFICIAL:
BFS
MIL-B-46176
(SD), Type II
P-D-680
ROBERT M. JOYCE
Major General, United States Army
The Adjutant General
DISTRIBUTION:
To be distributed in accordance with DA Form 12-
25B, Operator and Organizational maintenance
requirements for Drier-Mixers.
TA220072
CARD 5 OF 5