TM 5-3895-373-34
2.43
REPLACE/REPAIR AUXILIARY VIBRATION PUMP - Continued
A.
REMOVE.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
Thoroughly clean hydraulic hoses
and fittings before disconnecting.
Always plug or cap off disconnected
fittings
to
prevent
intrusion
of
contaminates. Failure to properly
clean and cap off connectors may
result
in
hydraulic
system
contamination
and
equipment
damage.
1.
REMOVE HYDRAULIC HOSES.
a.
Place machinery wiping towel below auxiliary
vibration pump.
b.
Using combination wrench, tag and disconnect
suction hose (1), return hose (2), and outlet hose
(3).
c.
Plug hoses (1, 2, and 3) and cap exposed
adapters with protective caps.
d.
Dispose
of
machinery
wiping
towel
in
accordance with local procedures.
GO TO NEXT PAGE
2-584