TM 5-3895-373-20
A.
REMOVE - Continued.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
b.
Check hydraulic oil level at sight liquid indicator.
Hydraulic oil must be below sight liquid indicator.
If necessary, drain oil until level falls below the
sight liquid indicator level. Refer to paragraph
2.23.8. Dispose of hydraulic oil in accordance
with local procedures.
c.
Remove hex head cap screws (8). Discard hex
head cap screws.
Do not allow any parts or material to
fall into hydraulic reservoir. Debris
may contaminate hydraulic oil or clog
system.
d.
Remove and discard sight liquid indicator (9) and
preformed packings (10).
e.
Wipe off sight liquid indicator mounting surface
with lint-free cloth.
GO TO NEXT PAGE
13-45