TM 5-3895-373-20
C.
INSTALL.
Hydraulic fitting sealant can cause eye
damage or skin irritation. Wash after
skin
contact.
Wear
safety
goggles/glasses
when
using.
Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water and
get immediate medical attention.
1.
APPLY HYDRAULIC FITTING SEALANT TO
ELBOW (6).
2.
INSTALL VIBRATION RELIEF VALVE (7) BY
CONNECTING STRAIGHT ADAPTER (5) TO
ELBOW (6) ON AUXILIARY VIBRATION PUMP
(8). POSITION RELIEF VALVE SO THAT
WHEN TIGHTENED, CAP NUT (9) IS ON TOP.
SEE THE ILLUSTRATION FOR CORRECT
POSITIONING.
3.
APPLY HYDRAULIC FITTING SEALANT TO
EXPOSED THREADS OF ELBOW (3) AND
STRAIGHT ADAPTER (4).
4.
CONNECT HOSES (1 AND 2) TO ELBOW (3)
AND STRAIGHT ADAPTER (4). TIGHTEN
HOSES.
NOTE
FOLLOW-ON-TASKS: Install right access cover per TM 5-3895-373-10.
Close right access door per TM 5-3895-373-10.
END OF TASK
13-25