TM 5-3895-373-20
A.
REMOVE - Continued.
2.
REMOVE DRIVE SCREW MOUNTED DATA
PLATE.
a.
Use diagonal cutting pliers or hammer and
chisel to back drive screws out of data
plate.
b.
If data plate is adhesive backed, use putty
knife
to
scrape
remaining
data
plate
material from paving machine.
WARNING
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
III cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
c.
If necessary, use cleaning cloths and
cleaning
solvent
to
remove
adhesive
residue from data plate mounting surface.
3.
REMOVE
BONDED
(ADHESIVE-BACKED)
DATA PLATE.
a.
Use scribe to lightly mark outline of data
plate mounting surface on paving machine.
Avoid scribing through all layers of paint.
b.
Use
putty
knife
to
scrape
damaged
equipment
data
plate
from
mounting
surface on paving machine.
GO TO NEXT PAGE