TM 5-3895-373-20
11.3.
REPLACE WALKWAYS, SCREED GUARD PLATES, AND SCREED HANDRAIL - Continued.
A.
REMOVE - Continued.
6.
REMOVE AND DISASSEMBLE OUTER STEP
SUPPORTS.
a.
Remove hex head cap screws (60), hex nuts
(61), lockwashers (62), and flat washers (63).
Discard lockwashers.
b.
Remove blower motor clamps (64) from blower
motors (65). Move the blower motors out of the
way for step support removal.
c.
Remove cushions (66 and 67).
d.
Remove bolts (68), hex nuts (69), and flat
washers (70) from vibration mounts (53).
e.
Remove vibration mounts (53) from outer step
supports. Discard vibration mounts.
f.
Remove hex head cap screws (71), hex nuts
(72), lockwashers (73), and flat washers (74).
Discard lockwashers.
g.
Remove outer step supports (75) from extension
screeds (76 and 77).
GO TO NEXT PAGE
11-22