TM 5-3895-373-20
7.12.
REPLACE/REPAIR WORK LIGHTS - Continued.
C.
INSTALL.
NOTE
Work lights (1 and 2) are assembled
with the light unit and bezel upside
down. The word TOP on the light
unit will be positioned at mounting
bracket (7).
1.
FOR REAR AND AUGER WORK LIGHTS
(1
AND
2),
INSTALL
MOUNTING
BRACKET (7) AND MACHINE SCREW
(8). FOR FORWARD WORK LIGHTS (3),
INSTALL
BRACKET,
SELFLOCKING
HEX NUT (9), AND MACHINE SCREW.
2.
POSITION WORK LIGHT (1, 2, OR 3)
ONTO
MOUNTING
BRACKET
(7).
SECURE WORK LIGHT TO BRACKET
WITH HEX HEAD CAP SCREW (5), AND
SELF-LOCKING NUT (6).
3.
APPLY
ELECTRICAL
INSULATING
COMPOUND
TO
CONNECTOR
(4).
RECONNECT WORK LIGHT (1, 2, OR 3)
AT CONNECTOR.
END OF TASK
7-108