TM 5-3895-373-20
A.
DISASSEMBLE - Continued.
2.
REMOVE
SECONDARY
LOCKS
FROM
CIRCUIT BREAKER TERMINALS.
a.
Insert
flat-blade
connector
remover
from
electrical connector repair tool kit into circuit
breaker terminal (4).
b.
Pry locking tab on secondary lock (5) from ledge
inside circuit breaker terminal by twisting flat-
blade connector removal tool toward center of
the terminal.
c.
With locking tab free, pull secondary lock (5)
from bottom of circuit breaker holder (6).
Discard secondary lock.
3.
REMOVE SECONDARY LOCKS FROM RELAY
TERMINALS.
a.
Insert flat-blade connector removal tool into relay
terminal (7).
b.
Pry locking tab on secondary lock (8) from ledge
inside
terminal
by
twisting
the
flat-blade
connector removal tool toward center of relay
terminal (7).
c.
With locking tab free pull secondary lock (8)
from bottom of relay holder (9). Discard
secondary lock.
GO TO NEXT PAGE
7-87