TM 5-3895-373-20
A.
REMOVE - Continued.
9.
REMOVE CIRCUIT BREAKER, TERMINAL,
AND
POWER
RELAY
FROM
RELAY
MOUNTING BRACKET.
a.
Remove self-locking nuts (82), wire 142
(83), and wires 103 (84) from circuit
breaker (85). Discard self-locking nuts.
Tag wires.
b.
Remove button head cap screws (86) from
circuit breaker (85).
c.
Remove circuit breaker (85) from relay
mounting bracket (87).
GO TO NEXT PAGE
7-33