TM 5-3895-373-20
B.
INSTALL - Continued.
2.
INSTALL STARTER CABLES AND ENGINE
HARNESS WIRES.
a.
Install
wire
333
(16)
onto
starter
ground
mounting stud. Install lockwasher (18) and hex
nut (17). Tighten hex nut to 42 lb-ft (57 Nm).
b.
Install wire 166 (15) and wire 332 (14) onto
starter S terminal. Install flat washer (13),
lockwasher (12), and hex nut (11) and tighten
hex nut.
NOTE
Do not use lockwasher that comes
with starter and is installed on starter
B terminal. Discard lockwasher.
c.
Install wire 331 (10) onto starter B terminal.
Install positive battery cable (9) and slave cable
(8). Install and tighten hex nut (7).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a well ventilated area. Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
d.
Coat starter B and S terminals with electrical
insulating varnish. Place rubber boot from slave
cable over starter B terminal.
GO TO NEXT PAGE