TM 5-3895-373-20
B.
INSTALL - Continued.
e.
Install clamps (32) onto radiator overflow
hose (33) and secure to radiator shroud
(34) with hex head cap screws (29),
lockwasher (30), and flat washer (31).
Tighten cap screws to 37 Ib-ft (50 Nm).
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush eyes with water and get
immediate medical attention.
f.
Clean threads of hex head cap screws (17
and 20) with thread locking compound
solvent.
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
g.
Apply thread locking compound to threads
of socket head cap screws (26).
h.
Position mounting plates (27 and 28) per L
(left) or R (right) markings on plates.
i.
Install mounting plates (27 and 28) and
socket head cap screws (26). Tighten cap
screws using hex head driver socket to 37
Ib-ft (50 Nm).
j.
Install flat washers (19 and 22) and
lockwashers (18 and 21) onto hex head
cap screws (17 and 20).
k.
Apply thread locking compound to threads
of hex head cap screws (17 and 20).
l.
Install spacers (25) and mounting brackets
(23 and 24).
m.
Install hex head cap screws (17 and 20).
Do not tighten cap screws at this time.
GO TO NEXT PAGE
6-5