TM 5-3895-373-20
B. INSTALL.
WARNING
Fuel is very flammable and can
explode easily. To avoid serious
injury or death:
Always wear safety glasses/goggles
at all times.
Keep fuel away from open flame or
any spark (ignition source).
Do not work on fuel system when
engine is hot; fuel can be ignited by a
hot engine.
Keep at least a B-C fire extinguisher
within easy reach when working with
fuel or on a fuel system.
Post signs that read "NO SMOKING
WITHIN 50 FEET" when working with
open fuel lines or fuel tanks.
1.
LUBRICATE PREFORMED PACKING (4) ON
FUEL
SHUTOFF
SOLENOID
(3)
WITH
PETROLATUM.
2.
INSTALL FUEL SHUTOFF SOLENOID (3) INTO
FUEL INJECTION PUMP.
3.
APPLY
ELECTRICAL
INSULATING
COMPOUND
TO
CONNECTOR
(2)
AND
QUICK DISCONNECT TERMINAL (1).
4.
INSTALL
CONNECTOR
(2)
AND
QUICK
DISCONNECT TERMINAL (1) ONTO FUEL
SHUTOFF SOLENOID.
NOTE
FOLLOW-ON-TASK:
Close front top left access door per TM 5-3895-373-10.
END OF TASK
4-33/(4-34 blank)