TM 5-3895-373-20
REFERENCE INFORMATION
PANEL GAUGE CIRCUIT
Refer to paragraphs 1.18.5 and 1.18.6 for
electrical system description for the panel
controls and indicators.
Refer to paragraph 7.21 for harness and lead
wire repair.
Refer to the electrical system diagram at the end
of the manual for equipment wiring details.
Temperature sensor resistance should vary with
coolant temperature as follows:
TEMPERATURE:
100
200
250
OHMS:
333
48
22
After completing diagnostic checks, close front
top left access door per TM 5-3895-373-10.
Install gauge panel per paragraph 7.6.
2-197