TM 5-3895-373-20
A.
REMOVE - Continued.
Thoroughly clean hydraulic hoses and
fittings before disconnecting. Always
plug or cap off disconnected fittings to
prevent intrusion of contaminants.
Failure to properly clean and cap off
connectors may result in system
contamination and equipment damage.
d.
Use a cleaning cloth and clean around the
hydraulic fittings on screed extension cylinder
(7).
e.
Place a machinery wiping towel below tube
fittings of tubes (9 and 10).
Hydraulic oil can be moderately
flammable and can be an irritant to the
skin, eyes, and respiratory system. Avoid
prolonged exposure. Eye protection and
rubber gloves must be worn when
working with hydraulic oil.
f.
Disconnect tubes (9 and 10) from straight
adapters (11 and 12).
g.
Install plugs into tubes (9 and 10) and caps
onto straight adapters (11 and 12) on screed
extension cylinder (7).
GO TO NEXT PAGE
15-79