TM 5-3895-373-20
15.4.
REPLACE/REPAIR CROWN ADJUSTMENT ASSEMBLY - Continued.
A.
REMOVE.
1.
DISCONNECT HYDRAULIC HOSES.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
Thoroughly clean hoses and fittings
before disconnecting. Always plug
or cap off disconnected fittings to
prevent intrusion of contaminants.
Failure to properly clean and cap off
connectors may result in system
contamination
and
equipment
damage.
a.
Place machinery wiping towels around fittings of
hydraulic hoses (I through 4).
b.
Wipe all dirt and dust from fittings of hydraulic
hoses (I through 4) with cleaning cloths.
c.
Tag and disconnect hydraulic hoses (1 through
4) from straight adapters (5 through 8). Drain oil
from hoses into a utility pail.
d.
Plug hydraulic hoses (1 through 4) and cap
straight adapters (5 through 8).
e.
Dispose of saturated machinery wiping towels
and waste hydraulic oil in accordance with
local procedures.
GO TO NEXT PAGE
15-32