TM 5-3895-373-20
C.
INSTALL - Continued.
j.
Install mounting panel (60) and secure with
tapping screws (56), leaving one screw out to
allow for connection of ground wires.
k.
Apply electrical insulating compound to inside
terminals
of
electrical
connector
(59)
and
connect to valve harness.
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a well ventilated area. Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
I.
Install ground wires 17 (57) and G201 (58) and
remaining tapping screw (56). Apply electrical
insulating varnish to wires and screw.
m. Install buss bar mounting bracket (53). Secure
with flat washers (52) and machine screws (51).
n.
Install circuit breakers (55), buss bar (54), and
wires. Refer to wiring diagram. Secure buss bar
and wires with self-locking nuts (50). Apply
electrical insulating varnish to wire terminals.
GO TO NEXT PAGE
15-13