TM 5-3895-373-20
A.
REMOVE - Continued.
d.
Remove tapping screw (56) and ground wires 17
(57) and G201 (58).
e.
Unplug electrical connector (59) from valve
harness.
f.
Remove three remaining tapping screws (56)
and mounting panel (60).
g.
With jewelers screwdriver remove machine
screws (61), hex nuts (62), lockwashers (63),
and protective cap (64). Discard lockwashers.
h.
Pull quick disconnect connector (65) from screed
control box through bottom of box.
GO TO NEXT PAGE
15-9